Enzyme-linked immunoassay of human type 1 collagen amino terminal peptide (NTX)

Enzyme-linked immunoassay of human type 1 collagen amino terminal peptide (NTX)

Kit instruction manual

This reagent is for research purpose only: This kit is used to determine the content of type 1 collagen amino terminal peptide (NTX) in human serum, plasma and related liquid samples.

Experimental principle:

This kit uses the double antibody sandwich method to determine the level of human type 1 collagen amino terminal peptide (NTX) in the specimen. Microporous plates were coated with purified human type 1 collagen amino terminal peptide (NTX) antibody to make solid phase antibodies. Type 1 collagen amino terminal peptide (NTX) was added to the microwells coated with mAb in turn, and then labeled with HRP The type I collagen amino terminal peptide (NTX) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex, and after thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the type 1 collagen amino terminal peptide (NTX) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human type 1 collagen amino terminal peptide (NTX) in the sample was calculated by a standard curve.

Kit composition:

Kit composition

48 hole configuration

96-well configuration

save

Instructions

1 serving

1 serving

Sealing film

2 pieces (48)

2 pieces (96)

sealed bag

1

1

Enzyme coated plate

1 × 48

1 × 96

Store at 2-8 ℃

Standard product: 22.5nmol / L

0.5ml × 1 bottle

0.5ml × 1 bottle

Store at 2-8 ℃

Standard dilution

1.5ml × 1 bottle

1.5ml × 1 bottle

Store at 2-8 ℃

Enzyme reagent

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Sample diluent

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Developer A liquid

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Developer B liquid

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Stop solution

3ml × 1 bottle

6ml × 1 bottle

Store at 2-8 ℃

Concentrated washing liquid

(20ml × 20 times) × 1 bottle

(20ml × 30 times) × 1 bottle

Store at 2-8 ℃

Sample processing and requirements:

1. Serum: room temperature blood coagulates naturally for 10-20 minutes, centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully and centrifuge again if a precipitate appears during storage.

2. Plasma: EDTA or sodium citrate should be selected as the anticoagulant according to the requirements of the specimen, mixed for 10-20 minutes, and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.

3. Urine: collected in a sterile tube and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, centrifuge again. Pleural and ascites, cerebrospinal fluid reference implementation.

4. Cell culture supernatant: When detecting secreted components, collect with a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When detecting the components inside the cells, dilute the cell suspension with PBS (PH7.2-7.4), and the cell concentration will reach about 1 million / ml. Through repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.

5. Organize the specimen: after cutting the specimen, weigh it. Add a certain amount of PBS, PH7.4. Quickly freeze and save with liquid nitrogen for later use. After the specimen melts, it still maintains a temperature of 2-8 ° C. Add a certain amount of PBS (PH7.4) and homogenize the specimen with a manual or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. After aliquoting, a portion is to be tested, and the rest is frozen for future use.

6. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

7. The sample containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP).

Steps:

1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of standard products in the first and second wells, and then add standard products in the first and second wells 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard diluent to the third and fourth wells respectively, mix well; Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentrations are 15nmol / L, 10nmol / L, 5nmol / L, 2.5nmol / L, 1.25nmol / L).

2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the test sample (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.

3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.

4. Mixing solution: Dilute 30 times (20 times of 48T) concentrated washing liquid with distilled water 30 times (20 times of 48T) and then use.

5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat this 5 times, pat dry.

6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.

7. Incubation: The operation is the same as 3.

8. Washing: The operation is the same as 5.

9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.

10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).

11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

Precautions:

1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.

2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.

3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.

4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).

5. The sealing film is limited to one-time use to avoid cross-contamination.

6. Please keep the substrate away from light.

7. Strictly follow the instructions, and the test results must be determined by the microplate reader.

8. All samples, washing liquids and various wastes should be treated as infectious agents.

9. The components of different batches of this reagent shall not be mixed.

10. If there is any difference with the English manual, the English manual shall prevail.

Calculation:

Taking the concentration of the standard as the abscissa and the OD value as the ordinate,

Draw a standard curve on coordinate paper, according to the OD of the sample

The value is determined by the standard curve; then multiplied by the dilution

Multiple; or calculate the standard using the concentration and OD value of the standard

The linear regression equation of the quasi-curve, the OD value of the sample

Substitute into the equation, calculate the sample concentration, and multiply by the dilution

The multiple is the actual concentration of the sample.

(This picture is for reference only)

Kit performance:

1. The correlation coefficient R between the linear regression of the sample and the expected concentration is above 0.95.

2. The batch and approval shall be less than 9% and 11% respectively

examination range:

0.7nmol / L -20nmol / L

Storage conditions and validity period:

1. Store the kit: 2-8 ℃.

2. Validity: 6 months

Aerial Working Truck

Aerial Working Truck, Aerial work truck, Sky lift truck, Overhead working truck transport refers to the staff and equipment to the site to be used and air operations of special vehicles.
use
Aerial Working Truck Crank arm type overhead working truck can overhanging operation, across some obstacles or in a lift can be carried out more work; Platform capacity big, for two or more people work at the same time and can carry a certain device; Lift platform mobility, convenient transfer site; Beautiful shape, suitable for indoor and outdoor operation and storage. Applicable to the station, wharf, shopping malls, sports venues, residential property, factories workshop and so on a wide range of aerial work.
Folding boom overhead working truck trailer type, mobile convenience, folding boom compact structure, adopts the new type of high quality steel, high strength, light weight, direct access to the alternating current (ac) or use dc power start itself, construction speed is quick, table can be increased and horizontal extension, also can rotate, the obstacles to reach the working position, is the ideal aerial work equipment.
In both assignments in the bucket and rotary seat is equipped with control devices, remote control of engine start/stop, high speed/low speed, adopting electro-hydraulic proportional valve control arm movements, good stability, working arm can be right and left 360 째 continuous rotation, tank level automatic linkage for homework, main pump failure emergency pump down homework groove can be manipulated, and night lighting, lifting heavy objects. Car leg alone separate, adjustable, can realize the vehicle on uneven road leveling. Can the vehicle mobile and convenient, suitable for narrow area, a side operations. Products are widely used in electricity, street lamp, municipal, gardens, communications, airport, built (revised) ship, transportation, advertising, photography, and other areas of the aerial work.
Multifunctional and multipurpose
Through the big arm front bracket, can be quickly installed lifting device or platform, realize the material function such as lifting, lifting, and manned aerial work, at the same time to extension assignments device and a variety of work device quickly switch provides the interface.
3 d rotation lift
Design three-dimensional rotating lift device, already can keep by lifting material profile automatically, and can realize the lifting materials in space any height, any location and any direction adjustment request, sensitive speed control precision, micro performance is good, can meet the large underground structure in high altitude and ventilation pipe installation requirements.
Aerial Working Truck classification
According to the form of its lifting mechanism, generally can be divided into the telescopic arm type (ZhiBeiShi), folding arm type (crank arm type), vertical lift and hybrid four basic forms, etc.

Aerial Working Truck,High-altitude Operation Truck,Overhead Working Truck,Jmc Aerial Working Truck,Bucket Work Truck

CLW GROUP TRUCK , https://www.clwgrouptruck.net