Common quality problems and countermeasures One. Missing posts (missing posts) 1. High stacking of signatures should reduce the stacking height of the signatures. 2. The front and rear gauges of the book stack are tightly clamped, and the gap should be properly adjusted. 3. If the suction volume of the suction nozzle is too small, the suction force should be increased. 4. The nozzle is worn and should be replaced. 5. The nozzle stem and valve are blocked and should be cleaned regularly. 6. The opening time and closing time of the cavities do not match with the oscillating position of the nozzle. The patting time should be adjusted and the hem position of the suction nozzle should be matched with the opening and closing time of the cavities. 7. Regularly check the missing patch detection device to ensure its sensitivity. 2. More posts (heavy posts) 1. The support page is loose and does not hold the signature completely. It should be adjusted to a proper position to hold the signature. 2. When the suction nozzle is low and the swinging amplitude is small, the nozzle height and swinging amplitude should be adjusted. 3. If the book stacking is not mixed, you should break the book off and regularly check the multiple posts detection device. Ensure its reliability. 4. Multi-poster and post-card auto-removal institutions are not properly adjusted, and when discarding waste books is not timely, the corresponding cam industry position should be selected according to the length direction of the book's post to prevent the multi-post and less-post book from being mixed into the finished book. Three wrong posts Operators are required to carefully check the layout and page number of their posts in order to prevent mistakes, and to stack semi-finished products at the same time. It is necessary to implement spot checks for every three or every ten spot checks conducted by spot-checkers; , found the wrong posts in a timely manner. Four. Dispatch (inverted) 1. Improper adjustment of the collection chain should align the dial on the set chain. 2. Tooth occlusions are tight, and when the placards are fast, the cavities should be adjusted so that the speed of the plackets is basically the same. 3. If the angle of the shutter is not proper, the angle of the shutter should be adjusted. 4. The signatures of the book are inconsistent and the signatures are not in place. Clearances should not be made. V. Damage to the signature 1. The paper is thin and poor, and the sucking force of the suction nozzle is too large. 2. The tusks are tight and break the signature. 3. The stacking of the signatures is high. When the last affixed signature is sucked away, drag the top page of the placard down and tear it. 4. The automatic control system is not working properly, and the signature is damaged when it is indiscriminately posted. 5. The tightness of the two fangs is inconsistent, tearing the pages. The above phenomenon should be solved one by one. Follow-up on the quality problems and solutions. Poly L-lactide-co-glycolide PLGA
Poly(lactic-co-glycolic acid) is a copolymer which is used in a host of Food and Drug Administration approved therapeutic devices, owing to its biodegradability and biocompatibility. PLGA are currently widely used in many fields, such as bone nail; coatings; lifting thread; absorbable suture; microspheres, gel for drug delivery etc.
The CAS Registry number of Poly(L-lactic acid) PLLA is 30846-39-0. It is white powder or floccule.
What we can do are PLGA5050,PLGA7525,PLGA8515,PLGA9010,etc.
We can provide Intrinsic viscosity from 0.30-2.25 dl/g, Mw from 6000-30000.
For each batch a certificate of analysis is provided, showing the analytical data determined in our quality control laboratory. Additional analytical data can be made upon request.
When stored in the original packaging at low temperatures (2-8°C), PLGA keeps its initial properties for at least two years.
RIMLESS is the exclusive distributor, exporter and global brand licensor of REBORN. We take REBORN and RIMLESS as the core brands, biomedical materials and their applications in the medical field as the main business, and the high-end medical devices as the research and development direction.
With the further development of science and technology, China's printing technology has been fully upgraded. Prepress, printing, and postpress technologies are all moving toward higher, faster, and more refined technologies, especially over the years. Bookbinding technology has also been rapidly developed. The binding of our factory has also taken place in these years. We have introduced the most powerful Martini Adhesive Production Line from the high starting point to provide more reliable protection for the production cycle and quality of books and periodicals. Vitality, with our factory binding as an example, I talk about the product quality problems prone to occur in various processes, only for the whole plant, the entire workshop peer reference.
We have exported over 50 countries and areas in the world and won a very good reputation and long-term partnership with our customers.
Medical Grade Copolymer PLGA,Biomedical Poly L-lactide-co-glycolide,Poly L-lactide-co-glycolide Polimer,Poly L-lactide-co-glycolide
Rimless Industry Co.,Ltd. , https://www.rimlessmedbeauty.com