Instruction manual of rat atrial natriuretic peptide receptor ELISA kit

Instruction manual of rat atrial natriuretic peptide receptor ELISA kit
This kit is for research use only.

Drug Name:
Generic name: Rat Atrial Natriuretic Peptide Receptor ELISA Kit

purpose of usage:
This kit is used to determine the content of natriuretic peptide receptors in central atrial natriuretic peptide of rat serum, plasma, or other tissue fluids.

Experimental principle
This kit uses the double antibody sandwich method to determine the level of rat atrial natriuretic peptide receptors in the specimen. Microporous plates were coated with purified anti-atrial natriuretic peptide receptor antibody to prepare solid-phase antibodies. Atrial natriuretic peptide receptor was added to the monoclonal antibody-coated microwells in turn, followed by HRP labeled atrial natriuretic peptide The receptor antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the atrial natriuretic peptide receptor in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of rat atrial natriuretic peptide receptor in the sample was calculated by a standard curve.

Kit composition
1
20 times concentrated washing liquid
50ml × 1 bottle
7
Stop solution
3ml × 1 bottle
2
Enzyme reagent
3ml × 1 bottle
8
Standard product (90 ng / L)
0.5ml × 1 bottle
3
Enzyme coated plate
12 holes × 4 strips
9
Standard dilution
1.5ml × 1 bottle
4
Sample diluent
10ml × 1 bottle
10
Instructions
1 serving
5
Developer A liquid
3ml × 1 bottle
11
Sealing film
2 sheets
6
Developer B liquid
3ml × 1 / bottle
12
sealed bag
1

Specimen requirements
1. Experiment as soon as possible after specimen collection.
2. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
3. The specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

Steps
1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of the standard products in the first and second wells, and then add the standard products in the first and second wells. 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard diluent to the third and fourth wells respectively, mix well; Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentrations are (60ng / L, 40ng / L, 20ng / L, 10ng / L, 5ng / L).
2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.
4. Mixing solution: dilute 20 times concentrated washing liquid with distilled water 20 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat this 5 times, pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

Calculation
Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.

Precautions
1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 1000).
5. Strictly follow the instructions, and the test results must be determined by the reading of the microplate reader
6. Please keep the substrate away from light.
7. The sealing film is limited to one-time use to avoid cross-contamination.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.

Detection range: 3ng / L-80ng / L
Specification: 96 servings / box

Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months
Xiamen Huijia Biotechnology Co., Ltd. is a professional agent for many well-known brands in the international life science field. Committed to the sales and promotion of various ELISA kits, immunohistochemical kits, primary and secondary antibodies, cytokines, biological reagents, pipettes, and consumables.

Paper Towel Holder

 

The perfect Kitchenware to storage the paper towel in kitchen and let the kitchen more clean.

Our stainless steel paper holder is constructed entirely of metal, with a bright stainless steel finish.

For our Paper Towel Holder , The weighted stainless steel base and EVA to keep the Paper Towel Holder in place.

Any items suitable for you, welcome to ask for more details and the sample.

Will be glad to hear from you.

 

Description of Paper Towel Holder


Material: base:SS410/Iron

tube:SS201/Iron

Finishing: Satin polishing ,Mirror Polishing ,Color painting

Logo: Laser logo, Etching logo, Silk printing logo, Embossed logo, Decal logo

MOQ : 2000 PCS

Packaging : White box, Mail box or Customized package

Sample Time : 7~10 days

Lead Time :60 days after have the deposit

Payment: T/T ,L/C or others

Payment term: 30% deposit before production and 70 % balance against the copy B/L


tissues holdertissues holder

tissues holder and mug tree


FAQ:


1:How can I get the sample?

We can provide the sample for customers to check the quality.

Please kindly provide the delivery info for calculate the sample cost. If you have DHL /TNT/UPS/FEDEX account, please also kindly provide it to us.

You can do the payment of sample via T/T and PayPal.

2:How about the sample time?

Usually the sample time is 7~10 days after have the sample cost.


3:How long will it take for mass production?

Usually 45~60 days after have the deposit.


4:Can we have our logo or company name to be printed on your products or the package?

Welcome OEM.


5:what certificate can you provide?

CE,CB,GS,FDA,LFGB,ROHS are available here.


6:How can we get your monthly new products announcement?

Please join our mailing lists.

Paper Towel Holder

Standing Paper Towel Holder,Kitchen Paper Towel Holder ,Stainless Steel Paper Towel Holder,Vertical Countertop Paper Towel Stand

Jiangmen Wellway Houseware Co.,Ltd , https://www.wellwayhouseware.com