Manual of Human Interleukin 6 (IL-6) Elisa Kit

The company specializes in supplying Elisa kits, quality assurance, price concessions, and can provide free testing services, please call to consult!

This kit can only be used for scientific research, not for medical diagnosis.

Human interleukin 6 (IL-6) quantitative detection kit (ELISA)

user's Guide

【Human interleukin 6 (IL-6) ELISA kit name]

Human interleukin 6 (IL-6) quantitative detection kit (ELISA)

【Use of human interleukin 6 (IL-6) ELISA kit kit】

Quantitatively detect the content of interleukin 6 (IL-6) in human serum, plasma and related liquid samples.

[Principle of Human Interleukin 6 (IL-6) ELISA Kit]

This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated human interleukin 6 (IL-6) monoclonal antibody transparent enzyme label coated plate. After incubation for a sufficient time, wash to remove unbound components, and then add the enzyme label After incubating the working solution for a sufficient period of time, wash to remove unbound components. Add substrates A and B in sequence. The substrate (TMB) is converted into a blue product catalyzed by horseradish peroxidase (HRP) and turns yellow under the action of acid. The concentration of 6 (IL-6) is positively correlated. The OD value is measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the content of human interleukin 6 (IL-6) in the sample is calculated.

[Composition of Human Interleukin 6 (IL-6) ELISA Kit Kit]

1

Enzyme coated plate

12 holes × 8

7

Developer A liquid

6mL

2

Standard

0.3mL × 6 tubes

8

Developer B liquid

6mL

3

20 times concentrated washing liquid

25mL

9

Stop solution

6mL

4

Sample diluent

6mL

10

Instructions

1 serving

5

Special diluent

6mL

11

Sealing film

2 sheets

6

Enzyme reagent

6mL

12

sealed bag

1

Remarks: The concentration of standard products (No. 1 → No. 6) is: 8, 4, 2, 1, 0.5, 0.25 pg / mL.

[Reagents and equipment not required by human interleukin 6 (IL-6) ELISA kit]

1. 37 ℃ thermostat

2. Standard specification microplate reader

3. Precision pipettes and disposable tips

4. Distilled water

5. Disposable test tubes

6. Absorbent paper

[Operation steps of human interleukin 6 (IL-6) ELISA kit]

1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.

2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.

3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, sample wells to be tested and blank control wells, record the positions of each well in the standard wells. Add 50μL of standard product; first add 10μL of sample to be tested, and then add 40μL of sample diluent (that is, the sample is diluted 5 times); blank control well is not added.

4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with the washing solution, let stand for 1min, shake off the washing solution, pat dry on the absorbent paper, repeat the washing 4 times (you can also use the washing machine to press Instructions for washing the board).

6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.

7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

8. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).

9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution, mix for 30s with a plate mixer (or gently shake for 30s by hand), and avoid color development at 37 ℃ for 15min .

10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow).

11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.

12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.

[Sample requirements for human interleukin 6 (IL-6) ELISA kit]

1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).

2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

3. The sample should be fully centrifuged, without hemolysis and particles.

【Precautions for Human Interleukin 6 (IL-6) ELISA Kit】

1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.

2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.

3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.

4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.

5. The quantitative range of this kit is 0.25-8pg / mL, beyond this range, it is calculated from the extension of the standard curve, not as an accurate quantitative result, please dilute it with a special diluent to determine the accurate result (within the range of 0.25-8pg / mL) ), Multiplied by the total dilution factor is the final concentration of the sample.

6. If the color is too light, the substrate incubation time can be extended properly.

7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.

8. The kits are used within the warranty period, and different batches of reagents should not be mixed.

9. Substrate B is sensitive to light and avoid prolonged exposure to light.

【Summary of operating procedures of human interleukin 6 (IL-6) ELISA kit】

Prepare reagents, samples and standards

Add prepared samples and standards, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes

Add stop solution

Read OD value within 15 minutes

Calculation

【Human interleukin 6 (IL-6) ELISA kit detection range】

0.25pg / mL-8pg / mL

【Specification of Human Interleukin 6 (IL-6) ELISA Kit】

96 servings / box

【Storage of Human Interleukin 6 (IL-6) ELISA Kit】

Store at 2-8 ℃, protected from light and moisture.

【Human interleukin 6 (IL-6) ELISA kit validity period】

6 months

Console Table

Console table is a versatile piece of furniture that is typically narrow and designed to be placed against a wall. It is commonly used in entryways, hallways, living rooms, and other areas where additional surface space and decorative elements are desired. Console tables offer both functionality and style. Here are some key features and aspects of a console table:

  1. Size and Shape: Console tables are typically long and narrow, allowing them to fit against walls without protruding too much into the room. They come in various lengths, heights, and depths, so you can choose a size that suits your available space and specific needs.

  2. Material and Construction: Console tables are made from a variety of materials, including wood, metal, glass, or a combination of these. The choice of material can impact the overall style and durability of the table. Consider the existing decor and the desired aesthetic when selecting the material for the console table.

  3. Design and Style: Console tables come in a range of designs and styles to match different interior themes. They can be traditional, modern, rustic, industrial, or have a unique and eclectic design. Consider the overall decor of the room and choose a console table that complements the existing style.

  4. Surface and Storage Options: The surface of a console table provides a convenient space to display decorative items such as vases, lamps, artwork, or family photos. Some console tables may also have additional storage features such as drawers, shelves, or cabinets. These can be useful for organizing small items like keys, mail, or other essentials.

  5. Functionality: Console tables serve various functional purposes. They can be used as a drop-off point for keys and wallets in entryways, a surface for setting down items in a hallway, or as a display area for decorative elements. In living rooms, console tables can be positioned behind sofas to hold lamps, books, or other accessories.

  6. Versatility: Console tables can be used in different areas of the home, making them versatile pieces of furniture. They can add functionality and style to entryways, dining rooms, bedrooms, or even home offices. Their narrow profile allows them to fit in spaces where larger tables might not be suitable.

  7. Mirror Pairing: Console tables are often paired with mirrors hung above them, creating an elegant and visually appealing display. The mirror enhances the overall look of the table and can make the space appear larger and brighter.



Hidden Pull Out Desk,Pull Out Desk Extension,Console Table Bookshelf,Desk with Pull Out Shelf,Computer Desk with Keyboard Tray

Ningbo Greenly Industy Co.,LTD. , https://www.chinagreenly.com