Introduction to Mifare Light Contactless IC Card

Overview

The UltraLight card is a 512-bit contactless IC card.

Electrical characteristics

The capacity is 512 bits, divided into 16 pages, 4 bytes per page

Programmable lock read-only function per page

32-bit user-definable one-time programming area

384-bit user read and write area

Data can be retained for 2 years and can be rewritten 1000 times

Unique 7-byte serial number

Working frequency: 13.56MHZ

Communication rate: 106KB baud rate

Anti-collision: multiple cards can be processed at the same time

Reading and writing distance: within 100mm (related to the antenna)

No power in the card

Storage structure

The UltraLight card has a total of 512 bits and is divided into 16 pages with 4 bytes per page. The storage structure is as follows:

Page number

Byte 0

Byte 1

Byte 2

Byte 3

Description

0

SN0

SN1

SN2

BCC0

Serial Number

1

SN3

SN4

SN5

SN6

Serial Number

2

BCC1

Reserved

Lock0

Lock1

Hold / Lock

3

OTP0

OTP1

OTP2

OTP3

OTP

4

Data0

Data1

Data2

Data3

Data read/write

5

Data4

Data5

Data6

Data7

Data read/write

6

Data8

Data9

Data10

Data11

Data read/write

7

Data12

Data13

Data14

Data15

Data read/write

8

Data16

Data17

Data18

Data19

Data read/write

9

Data20

Data21

Data22

Data23

Data read/write

10

Data24

Data25

Data26

Data27

Data read/write

11

Data28

Data29

Data30

Data31

Data read/write

12

Data32

Data33

Data34

Data35

Data read/write

13

Data36

Data37

Data38

Data39

Data read/write

14

Data40

Data41

Data42

Data43

Data read/write

15

Data44

Data45

Data46

Data47

Data read/write

(1) Pages 0 and 1 contain information such as the serial number of the card and are only readable. The check digits are calculated according to ISO/IEC 14443-3 as follows:

BCC0=CT⊕SN0⊕SN1⊕SN2

BCC1=SN3⊕SN4⊕SN5⊕SN6

(2) Page 2 is LOCK BYTES. Setting the bits corresponding to Byte 2 and Byte 3 can be individually locked from the 3rd page to the 15th page as a read-only area.

Lock0

L

7

L

6

L

5

L

4

L

OTP

BL

15-10

BL

9-4

BL

OTP

Lock1

L

15

L

14

L

13

L

12

L

11

L

10

L

9

L

8

Lx locks X pages as read only

BLX locks the corresponding Lx bit

Note: Once the block-locking (BLX) bit is set to the locked configuration, the corresponding memory area will be frozen. For example, if BL15-10 is set to 1, then L15 to L10 can no longer be changed.

Lock0 and Lock1 can be set by a write command, and the written content is bit or operated with the current content to obtain new content, and the initial value is 0. This process is irreversible. If a bit is set to 1, it can no longer be set to 0.

(3) Page 3 is OTP, which is one-time programming, and the initial value is 0. It is possible to change its value by writing a command, and the written value and the current value are bitwise ORed to obtain a new value. This process is irreversible. If a bit is set to 1, it will no longer be set to 0.

Note: This memory area can be used as a one-time counter with a maximum of 32.

(4) Pages 4 to 15 are the user read/write areas with an initial value of 0.