I. General requirements 1. The building thermal engineering design of nurseries and kindergartens should be compatible with the regional climate, and should comply with the zoning requirements and related regulations in the “Civil Building Thermal Engineering Design Regulationsâ€. 2. The living room for nurseries and kindergartens must be set up according to regulations. Services and supply rooms can be set on different scales. 2.1 Living rooms include activity rooms, dormitory rooms, nursery rooms, milking rooms, nursing rooms, toilets (including toilets, toilets, baths), clothes storage rooms, and sound and activity rooms. Full-time care The activity rooms and dormitory rooms of children's and kindergartens should be combined. 2.2. The service rooms include the medical health room, isolation room, morning inspection room, childcare value room, staff office, meeting room, duty room (including the mail room), and staff toilets, bathrooms, etc. Full-time nurseries and kindergartens do not have a childcare room. 2.3. Supply houses include children's kitchens, disinfection rooms, boiled water rooms, laundry rooms and warehouses. The layout of the plane should be clearly partitioned, avoid mutual interference, facilitate the use of management, and facilitate the evacuation of traffic. It is forbidden to place children's living rooms in the basement or semi-basement. The indoor net height of living houses should not be lower than the following table. Second, other provisions The net height of the special shape of the ceiling and the minimum distance from the ground should not be lower than 2.2.0m. Nursery, kindergarten architectural modeling and interior design should meet the characteristics of young children. Nursery and kindergarten living rooms should be placed in the best sunshine position in the area and meet the requirement of no less than 3 hours (hours) for the full moon window on the winter solstice season. Living rooms in hot areas should be avoided from facing west. Otherwise, shading facilities should be provided. The ratio of the window area of ​​the building's side windows to the light should not be less than that specified in the table below. For single-side lighting, the ratio of the room depth to the floor height above the window should not be greater than 2.5. The room allowable noise level in sound and body activity room, activity room, dormitory room, isolation room should not exceed 50dB, the air soundproofing sound insulation volume RW of partition walls and floors should not be less than 40dB, and the floor weighting standardized sound pressure level Should not exceed 75dB. Third, kindergarten living room 1) The area of ​​living room for kindergartens should not be less than the requirements in Table 3.2.1. 2) The boarding room, dormitory, bathroom, and clothes storage room of the boarding kindergarten should be designed as life units for each class. 3) The unilateral lighting room should not exceed 6.60m in depth. The floor activity room should set up a terrace or balcony for outdoor activities, but it should not cover the sunshine of the ground floor. 4) Infant toilets should meet the following requirements: The toilet should be close to the activity room and dormitory. Toilets and toilets should be separated or separated. There should be direct natural ventilation. When a full-time kindergarten activity room is combined with a dormitory, the area is calculated as 80% of the sum of the two areas. When full-time kindergartens (or boarding kindergartens have centralized bathing facilities), the toilet area per class can be reduced by 2m2. When boarding nurseries and kindergartens set up a bathroom, the area should be determined according to the size. For experimental or demonstration kindergartens, certain professional houses and equipment may be added as appropriate, and their use area shall be set according to the requirements of the design task book. The height of the wash basin is 0.50-0.55m, the width is 0.40-0.45m, and the tap spacing is 0.35-0.4m. 5) No matter whether the trough or seat type toilets are used, there should be 1.2m high overhead partitions and handrails should be added. Each toilet seat has a plane size of 0.80m×0.70m, a groove type width of 0.16-0.18m, and a toilet seat height of 0.25-0.30m. Toilets in all classes in hot areas should have showers. Hot water bathing facilities should be set up centrally, and those separated into classes should be separate bathrooms. 6) The number of sanitary facilities in each toilet shall not be less than the requirements in Table 3.2.5. 7) The toilets used by nursing staff should be concentrated in close proximity or separated in class. 8) The location of the sound and activity room should be close to living rooms, and should not be mixed with services and supply rooms. When set up separately, it is advisable to connect the corridor to the main building. IV. Nursery living room 1) The nurseries are divided into baby classes and nursery classes. The room setup and minimum use area of ​​the infants' classes should meet the requirements in the table below. The area of ​​living room and related regulations for nursery classes are the same as for kindergartens. 2) Living rooms for baby and nursery classes should be designed as living units for each class. When nurseries and kindergartens are built together, the childcare section should be divided into separate sections and separate entrances and exits. 3) Feeding room and milking room should meet the following requirements: The nurse room and the nursery room should be close to the nursery room, and the nurse room should also be near the entrance and exit. Nurseries and nursing rooms should be equipped with sinks. The milking room should have heating facilities. When using contaminated fuel, there should be independent ventilation and smoke exhaust systems. 4) There should be two wash basins for the baby class toilets, one for the sinks and one for the nurses (also known as the pour tank). V. Service room 1) The area of ​​use of service rooms should not be less than the following table. 2) The medical health room and the isolation room should be set adjacent to each other. Children's living rooms should have a proper distance. If it is a building, it should be located on the ground floor. Medical health room and isolation 3) Kitchen design should meet the following requirements. When a nursery, a kindergarten's kitchen and a staff's kitchen are built together, the area may be slightly less than the sum of the two parts. When the main and non-staple food processing machinery is installed in the kitchen, the use area of ​​the main and subsidiary food processing rooms can be appropriately increased. Because of the different fuels in each area, whether or not the fire room is set up and the size of the area used should be determined according to local conditions. When nurseries and kindergartens are buildings, small vertical lifting ladders should be set 6. Fire Prevention and Evacuation 1) The fire protection design for nursery schools and kindergartens shall comply with the provisions of this section in addition to the national building design fire protection codes. 2) Children's houses in nurseries and kindergartens should not be located in four or more floors in buildings with first or second grade fire-resistance; buildings with third-class fire resistance should not be located in three or more floors; Fire-rated buildings should not exceed one floor. The flat roof can be used as a safety evacuation and outdoor playground, but it should have protective facilities. 3) Steps should not be provided for safe passage of infants and frequent exits and exits. If necessary, a non-slip ramp can be provided, and the gradient should not be greater than 1:12. 4) Stairs, handrails, railings and steps should meet the following requirements: In addition to adult handrails, stairs should be provided with handrails on the side of the wall. The height should not exceed 0.60m. The vertical distance between the vertical lines of the balustrade should not exceed 0.11m. When the net width of the stairwell is greater than 0.20m, safety measures must be taken. The height of stairs should not exceed 0.15m and the width should not be less than 0.26. Outdoor safety evacuation stairs installed in cold and cold areas should have anti-skid measures. Activity rooms, bedroom rooms, sound and activity rooms should have double swing doors, and their width should not be less than 1.20m. Swing doors, spring doors, and sliding doors should not be used in evacuation routes. The company's Sports Equipment Co., Ltd. mainly produces outdoor combination slides, kindergarten toys, children's furniture, outdoor development equipment, fitness equipment, naughty Fort, etc. It is a science and technology enterprise integrating design, production, sales, and after-sale. Website:. Advisory telephone. The company's pleasure and dedication to serve you! Factory address: No. 16, Chuangqiang Road, Lucheng District, Wenzhou City Light Industry Park. Curtain Draw Rod,Curtain Pulling Rods,Metal Curtain Draw Rods,Draw Rod For Curtains HANGZHOU AG MACHINERY CO.,LTD , https://www.famourdecor.com